dynamical system cable
"
Reparación de sonda endo-cavitatoria Ultrasonix EC9-5/10
Ultrasonix EC9-5/10 Endo-cavitary probe for repair ► Brief Description Fault: Bad array element. Solution: Replace crystal and housing. ►Problem & Solutoin BrandUltrasonix ModelEC9-5/10FaultBad array elementSolutionReplace crystal and housing ► Common issues with EC9-5/10 Probe Image Dropouts or Streaks (Dead Elements)Acoustic Lens DamageCable and Strain Relief DamageHousing or Casing Damage ►FAQHow can I tell if my EC9-5/10 has a crystal failure or a cable failure?Crystal
Richard Wolf 85525922 ENDOCAM Logic HD 3-Chip cabeza de la cámara
Richard Wolf 85525922 ENDOCAM Logic HD 3-Chip Camera Head ► Brief Description The Richard Wolf 85525922 is a professional-grade ENDOCAM Logic HD 3-Chip Camera Head. It is designed for high-end endoscopic imaging, offering superior color reproduction and clarity through its triple-sensor technology.It is a high-performance imaging component designed for minimally invasive surgery ,used in various surgical disciplines (Laparoscopy, Arthroscopy, etc.) to provide high-definition
Placa de conducción CCD de Endoscopio Flexible para el colonoscopio PENTAX EC-3890LK
CCD Driver Board For PENTAX EC-3890LK Colonoscope ► Brief Description The CCD Driver Board for the PENTAX EC-3890LK is a critical internal electronic component located within the video colonoscope. Its primary role is to drive the Charge-Coupled Device (CCD) image sensor located at the distal tip of the endoscope. It manages the precise timing signals required to capture high-resolution medical images and prepares the raw video data for transmission back to the main PENTAX
Olympus CCD para el broncoscopio BF-260 para procedimientos médicos
Olympus CCD for BF-260 Bronchoscope Spare parts of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF-XQ260,
Olympus CCD para GIF-XQ260 Gastroscopo con serie CCD
Olypmus CCD for GIF-XQ260 Gastroscope Spare parte of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF
Elemento de matriz lineal para la sonda L12-5
Array element for L12-5 probe ► Brief Description The L12-5 probe is a sophisticated linear array ultrasound transducer renowned for its versatility in high-resolution imaging. Its core functionality hinges on its array elements. ► Features Ultrasound Generation: Each element is capable of converting electrical energy into mechanical (ultrasound) vibrations. When an electrical pulse is applied, the element vibrates and generates a short burst of ultrasound waves. Echo
Ángulo derecho Adaptador de cable de luz de 90 grados para el paquete de guía de luz Karl Storz
Right Angle 90 degree Light Cord Adaptor For Karl Storz Light Guide Bundle ► Brief Description The Karl Storz Light Guide Bundle Adaptor is an accessory used in endoscopic and surgical lighting systems to connect light cables (light guides) to light sources or other optical components. Karl Storz is a leading manufacturer of medical and surgical equipment, particularly known for its high-quality endoscopes and illumination systems. ► Features Compatibility – Designed to work
S5-1 sonda de ultrasonido de la matriz de sectores para reparación
S5-1 sector array ultrasound probe for repair ► Brief Description Fault: Array element aging, lens bubble. Solution: Replace Crystal. ►Problem & Solutoin ModelS5-1FaultArray element aging, lens bubbleSolutionReplace Crystal ► Common issues with S5-1 Probe Image Dropouts / Dead ElementsAcoustic Lens DamageCable DamageConnector DamageWeak or Noisy Image ►FAQ What causes "dark shadows" or vertical dropouts on the S5-1 screen, and can it be fixed? A: Vertical black lines or blind
Olympus MAJ-1121 Transductor de Mano
Olympus MAJ-1121 Transducer Handpiece ► Brief Description The MAJ-1121 is a dedicated Remote Signal Cable designed for medical endoscopy systems. It serves as the communication bridge between the Olympus Video Processor and peripheral imaging devices. ► Features Signal Transmission: It relays trigger signals from the remote switches (buttons) located on the endoscope handle to external equipment.Workflow Integration: Enables the endoscopist to control capturing, printing, or