Calidad El gastroscopio Olympus GIF-H170 para su reparación Fabricación

El gastroscopio Olympus GIF-H170 para su reparación

Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube ...

Calidad Gastroscopio Olympus GIF-1TQ160 para reparación Fabricación

Gastroscopio Olympus GIF-1TQ160 para reparación

Olympus GIF-1TQ160 gastroscope for repair ► Brief Description Fault: 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip. Solution: Replace CCD, ...

Calidad Broncoscopio Olympus BF-XP160F para reparación Fabricación

Broncoscopio Olympus BF-XP160F para reparación

Olympus BF-XP160F fiber scope for repair ► Brief Description Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire, screw tube wear; ...

Calidad OLYMPUS CF-H180AL Colonoscopio electrónico para reparación Fabricación

OLYMPUS CF-H180AL Colonoscopio electrónico para reparación

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...

Calidad Olympus CF-H190L Colonoscopio para su reparación Fabricación

Olympus CF-H190L Colonoscopio para su reparación

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; ...

Calidad Gastroscopio Olympus GIF-Q150 para reparación Fabricación

Gastroscopio Olympus GIF-Q150 para reparación

Olympus GIF-Q150 gastroscope for repair ► Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace light bundle ...

Calidad Endoscopio Olympus TJF-160VR para su reparación Fabricación

Endoscopio Olympus TJF-160VR para su reparación

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The ...

Calidad Gastroscopio Olympus GIF-Q180 para reparación Fabricación

Gastroscopio Olympus GIF-Q180 para reparación

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light ...

Calidad El gastroscopio Olympus GIF-H180J para su reparación Fabricación

El gastroscopio Olympus GIF-H180J para su reparación

Olympus GIF-H180J gastroscope for repair ► Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, ...