Olympus CF-H190L Colonoscope for repair

1
MOQ
Negociable
Precio
Olympus CF-H190L Colonoscope for repair
Caracteristicas Galería Descripción de producto Pida una cita
Caracteristicas
Especificaciones
Marca: OLIMPO
Modelo: Se aplicará el procedimiento siguiente:
Falla: 1. Imagen OK; 2. Bundle ligero todavía está bien; 3. La parte delantera del tubo de inserción está r
Solución: Reemplace el tubo de inserción, el tubo de biopsia, la sección de flexión, el cable, el tubo de héli
Resaltar:

Olympus CF-H190L Colonoscope repair service

,

medical colonoscope repair with warranty

,

Olympus CF-H190L endoscope repair case

Información básica
Nombre de la marca: Careutech
Número de modelo: Se aplicará el procedimiento siguiente:
Pago y Envío Términos
Detalles de empaquetado: Paquete estándar
Condiciones de pago: T/t, unión occidental
Descripción de producto

Olympus CF-H190L Colonoscope for repair

 

 

 

Brief Description


 

Fault:

 

1. Image ok;

2. Light bundle still ok;

3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking;

4. Biopsy tube wear;

5. Left Angle failure, bending section, wire and helix tube wear;

6. Soft and hard adjustment wire wear, relatively tight;

7. Rubber leakage.

Solution:

 

Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD).

 

 

Problem & Solutoin

 

Brand Olympus
Model CF-H190L
Fault 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; 6. Soft and hard adjustment wire wear, relatively tight; 7. Rubber leakage.
Solution Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD)

 

 

 

Common issues with CF-H190L Colonoscope

 

  • No Image/Black Screen
  • Dim or Uneven Illumination
  • Blurry or Out-of-Focus Image
  • Stiff or Difficult Angulation
  • Leaking or Failed Leak Test
  • Abnormal Angulation
  • Biopsy Channel Obstruction
  • Damaged Bending Rubber
  • Buttons Not Responding
  • Water or Air Channel Issues

 

 

If your instrument has any of the above problems or others, please feel free to contact us for assistance. We will do our best to help you solve the issue.

 

 

About Us

 

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

 

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

 

What we can do